UV-VIS Spectrophotometer
Black03
UV- VIS Spectrophotometer is equipped with a sample holder. In addition, it is also integrated with 4 position selector control for varied lengths of cuvettes. High in demand for use in nutraceutical, food, life science, pharma, mining, semiconductor and refining industry, this spectrophotometer is offered to clients at highly competitive price. It also has the facility for automatic concentration. This machine is also capable of performing %T absorbance & K factor measurement.
Price Range : 2000.00 - 3000.00 USD ($)
UV-VIS Spectrophotometer Double beam
UVD-1800
UV-VIS Spectrophotometer Double beam
Technical Details: - Model: UVD-1800
- Optical System: Double beam
- Wavelength Range: 190~1100nm
- Band Width: 2nm (0.5, 1, 4, 5nm optional) or 0.5, 1, 2, 4nm adjustable
- Wavelength Accuracy: ±0.3nm
- Wavelength Repeatability: ≤0.1nm
- Photometric Accuracy: ±0.3% T(0-100%T) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
- Photometric Repeatability: 0.15% T(0-100%T) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
- Stray Light: ≤0.03% T (220nm NaI, 340nm NaNO2)
- Stability: 0.0005A/h@500nm
- Noise: ± 0.0002A @500nm
- Baseline Flatness: ± 0.001A
- Photometric Mode: T, A, C, E
- Wavelength Setting: Automatic
- Photometric Display Range: -4~4A
- Display Mode: 6 inches high brightness blue LCD
- Detector: Import Silicon Photodiode
- Light Source: Import Deuterium Lamp & Tungsten Halogen Lamp
- Power Requirement: AC 220V/50Hz 110V/60Hz
- Power: 120W
- Dimensions(WxDxH): 560×450×230mm
- Weight: 28Kg
UV-VIS Spectrophotometer UVD-1900
273
UV-VIS Spectrophotometer UVD-1900
Technical Details: - Model: UVD-1900
- Optical System: Double beam
- Wavelength Range: 190~900nm
- Band Width: 0.1, 0.2, 0.5, 1.0, 2.0, 4nm
- Wavelength Accuracy: ±0.3 nm
- Wavelength Repeatability: ≤0.1nm
- Photometric Accuracy: ±0.3% T(0-100%T) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
- Photometric Repeatability: 0.15% T(0-100%T) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
- Stray Light: ≤0.008% T (220nm NaI, 340nm NaNO2)
- Stability: 0.0005A/h@500nm
- Noise: ± 0.0002A @500nm
- Baseline Flatness: ± 0.001A
- Photometric Mode: T, A, C, E
- Wavelength Setting: Automatic
- Photometric Display Range: -4~4A
- Display Mode: 6 inches high brightness blue LCD
- Detector: Import Silicon Photodiode
- Light Source: Import Deuterium Lamp & Tungsten Halogen Lamp
- Power Requirement: AC 220V/50Hz 110V/60Hz
- Power: 120W
- Dimensions(WxDxH): 560×450×230 mm
- Weight: 28 Kg
UV-VIS Spectrophotometer UVS-1700
274
UV-VIS Spectrophotometer UVS-1700
Specification: - Model: UVS-1700
- Optical System: Single beam
- Wavelength Range: 190~1100 nm
- Band Width: 2nm (0.5, 1, 4, 5nm optional) or 0.5, 1, 2, 4nm adjustable
- Wavelength Accuracy: ±0.3 nm
- Wavelength Repeatability: ≤0.1 nm
- Photometric Accuracy: ±0.3% T(0-100%T) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
- Photometric Repeatability: 0.15% T(0-100%T) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
- Stray Light: ≤0.03% T (220nm NaI, 340nm NaNO2)
- Stability: 0.0005A/h@500nm
- Noise: ± 0.0002A @500nm
- Baseline Flatness: ± 0.001A
- Photometric Mode: T, A, C, E
- Wavelength Setting: Automatic
- Photometric Display Range: -4~4A
- Display Mode: 6 inches high brightness blue LCD
- Detector: Import Silicon Photodiode
- Light Source: Import Deuterium Lamp & Tungsten Halogen Lamp
- Power Requirement: AC 220V/50Hz 110V/60Hz
- Power: 120W
- Dimensions(WxDxH): 560×450×230 mm
- Weight: 28 Kg
UV-VIS Spectrophotometer UV-1500
275
UV-VIS Spectrophotometer UV-1500
Specification: - Wavelength Range: 190~1100 nm
- Band Width: 2nm
- Wavelength Accuracy: ±0.5nm
- Wavelength Repeatability: 0.2nm
- Photometric Accuracy: ±0.5% T
- Photometric Repeatability: 0.2% T
- Stray Light: ≤0.05% T (340nm NaNO2)
- Stability: 0.001A/30min@500nm
- Photometric Mode: T,A,C,E
- Wavelength Setting: Automatic
- Photometric Display Range: -0.3~3A
- Display mode: LCD Screen (128x64 Dots)
- Detector: Import Silicon Photodiode
- Light Source: Import Tungsten Lamp
- Power Requirement: AC 220V/50Hz 110V/60Hz
- Power: 120W
- Dimensions(WxDxH): 480×350×220 mm
- Weight: 15 Kg
UV-VIS Spectrophotometer UV-1300
276
UV-VIS Spectrophotometer UV-1300
Specification: - Wavelength Range: 190~1100nm
- Band Width: 4nm
- Wavelength Accuracy: ±0.5nm
- Wavelength Repeatability: 0.2nm
- Photometric Accuracy: ±0.5% T
- Photometric Repeatability: 0.2% T
- Stray Light: ≤0.05% T(340nm NaNO2)
- Stability: 0.001A/30min@500nm
- Photometric Mode: T,A,C,E
- Wavelength Setting: Manual
- Photometric Display Range: -0.3~3A
- Display mode: LCD Screen (128x64 Dots)
- Detector: Import Silicon Photodiode
- Light Source: Import Tungsten Lamp
- Power Requirement: AC 220V/50Hz 110V/60Hz
- Power: 120W
- Dimensions(WxDxH): 480×350×220mm
- Weight: 15Kg
UV-VIS Spectrophotometer UV-1100
277
UV-VIS Spectrophotometer UV-1100
Specification: - Wavelength Range: 200~1000 nm
- Band Width: 4nm
- Wavelength Accuracy: ±2.0nm
- Wavelength Repeatability: 0.2nm
- Photometric Accuracy: ±0.5% T
- Photometric Repeatability: 0.2% T
- Stray Light: ≤0.05% T (340nm NaNO2)
- Stability: 0.001A/30min@500nm
- Photometric Mode: T,A,C,E
- Wavelength Setting: Automatic
- Photometric Display Range: -0.3~3A
- Display mode: LCD Screen (128*64 Dots)
- Detector: Import Silicon Photodiode Detector
- Light Source: Import Tungsten Lamp
- Power Requirement: AC 220V/50Hz 110V/60Hz
- Power: 120W
- Dimensions(WxDxH): 460×330×210 mm
- Weight: 11 Kg
Visible Spectrophotometer V-1500
278
Visible Spectrophotometer V-1500
Technical Details: - Wavelength Range: 320~1100 nm
- Band Width: 2nm
- Wavelength Accuracy: ±0.5nm
- Wavelength Repeatability: 0.2nm
- Photometric Accuracy: ±0.5% T
- Photometric Repeatability: 0.2% T
- Stray Light: ≤0.05% T (340nm NaNO2)
- Stability: 0.001A/30min@500nm
- Photometric Mode: T,A,C,E
- Wavelength Setting: Automatic
- Photometric Display Range: -0.3~3A
- Display mode: LCD Screen (128*64 Dots)
- Detector: Import Silicon Photodiode
- Light Source: Import Tungsten Lamp
- Power Requirement: AC 220V/50Hz 110V/60Hz
- Power: 120W
- Dimensions(WxxDxH): 480×350×220 mm
- Weight: 11 Kg
UV-VIS Spectrophotometer Black09
281
UV-VIS Spectrophotometer Black09
Technical Details: - Wavelength Range: 190-1100 nm
- Bandwidth: 0.5/1/2/4/5nm
- Wavelength Accuracy: ±0.1nm(D2 656.1NM), ±0.3nm
- Wavelength Reproducibility: ≤0.1nm
- Photometric Accuracy: ±0.2%T
- Photometric Repeatability: ≤0.15%T
- Straylight: ≤0.03%T
- Stability: ±0.0004A/h(500nm)
- Baseline Flatness: ±0.0001A
- Noise: ±0.0005A
- Photometric Range: 0-200%T, -4.0--4.0A, 0-9999C
- Wavelength setting mode: Automatic
- Scanning speed: HI,MED,LOW,Optional
- Output: USB Port
- Printer port: Parallel Port
- Display: LCD(320x240)
- Light Source: Deuterium&Tungsten Halogen Lamp
- Detector: Silicon Photodiode
- Power: AC 220V/50Hz or 110V/60Hz
- Dimension: 625x430x210 mm
- Weight: 28 Kg
UV-VIS Spectrophotometer Black08
282
UV-VIS Spectrophotometer Black08
Technical Details: - Wavelength Range: 190-1100 nm
- Bandwidth: 1.8 nm
- Wavelength Accuracy: ±0.1nm(D2 656.1NM), ±0.3nm
- Wavelength Reproducibility: ≤0.1nm
- Photometric Accuracy: ±0.2%T
- Photometric Repeatability: ≤0.15%T
- Straylight: ≤0.03%T
- Stability: ±0.0004A/h(500nm)
- Baseline Flatness: ±0.0001A
- Noise: ±0.0005A
- Photometric Range: 0-200%T, -4.0--4.0A, 0-9999C
- Wavelength setting mode: Automatic
- Scanning speed: HI,MED,LOW, Optional
- Output: USB Port
- Printer port: Parallel Port
- Display: LCD(320x240)
- Light Source: Deuterium Tungsten Halogen Lamp
- Detector: Silicon Photodiode
- Power: AC 220V/50Hz or 110V/60Hz
- Dimension: 625x430x210 mm
- Weight: 28 Kg
UV-VIS Spectrophotometer Black05
283
UV-VIS Spectrophotometer Black05
Technical Details: - Wavelength Range: 190-1100 nm
- Bandwidth: 1.8nm
- Wavelength Accuracy: ±0.5nm(D2 656.1NM),±0.3nm
- Wavelength Reproducibility: ≤0.2nm
- Photometric Accuracy: ±0.3%T
- Photometric Repeatability: ≤0.15%T
- Straylight: ≤0.05%T
- Stability: ±0.001A/h(500nm)
- Baseline Flatness: ±0.0001A
- Noise: ±0.0005A
- Photometric Range: 0-200%T, -4.0--4.0A, 0-9999C
- Wavelength setting mode: Automatic
- Scanning speed: High, Middle, Low, Optional
- Output: USB Port
- Printer port: Parallel Port
- Display: LCD(320x240)
- Light Source: Deuterium Tungsten Halogen Lamp
- Detector: Silicon Photodiode
- Power: AC 220V/50Hz or 110V/60Hz
- Dimension: 460x380x180 mm
- Weight: 20 Kg
|